TM 10-4320-310-14
4-6.
SETUP INSTRUCTIONS Continued
(1) Insert ground cable into slot in ground stud and tighten.
(2) Connect coupling to ground rod and install driving stud. Make sure that driving stud seats on ground rod.
(3) Drive ground rod into ground until coupling is just above surface.
(4) Remove driving stud and install another section of ground rod making sure that it seats on first section.
(5) Install another coupling and driving stud. Drive ground rod until new coupling is just above ground
surface.
(6) Use a minimum of three sections of 3 foot length ground rods. Add additional sections until ground rod
has been driven sufficiently deep to provide effective ground.
(7) Remove driving stud and top coupling.
(8) Connect clamp and ground cable to ground rod and securely tighten screw.
4-7.
PRELIMINARY SERVICING AND ADJUSTMENT OF EQUIPMENT SETUP
Death or serious injury could occur if fuel
is not handled carefully. Use in a well
ventilated area away from open flame,
arcing
equipment,
ignition
sources,
heaters, or excessive heat. Engine must
be turned off and cool before refueling.
Use proper refueling procedures and
equipment to avoid spillage. Do not run
engine
near
open
fuel
containers.
Always store fuel in properly marked
containers. DO NOT SMOKE.
a.
Be sure fuel tank has sufficient fuel.
b.
With engine level, check oil level. remove oil
dipstick (1) and wipe with a lint free cloth. Insert oil
dipstick all the way into the engine. Withdraw dipstick.
Engine oil should coat oil dipstick to top mark (2).
4-3