TM 10-4320-310-144-6.SETUP INSTRUCTIONS Continued(1) Insert ground cable into slot in ground stud and tighten.(2) Connect coupling to ground rod and install driving stud. Make sure that driving stud seats on ground rod.(3) Drive ground rod into ground until coupling is just above surface.(4) Remove driving stud and install another section of ground rod making sure that it seats on first section.(5) Install another coupling and driving stud. Drive ground rod until new coupling is just above groundsurface.(6) Use a minimum of three sections of 3 foot length ground rods. Add additional sections until ground rodhas been driven sufficiently deep to provide effective ground.(7) Remove driving stud and top coupling.(8) Connect clamp and ground cable to ground rod and securely tighten screw.4-7.PRELIMINARY SERVICING AND ADJUSTMENT OF EQUIPMENT SETUPDeath or serious injury could occur if fuelis not handled carefully. Use in a wellventilated area away from open flame,arcing equipment, ignition sources,heaters, or excessive heat. Engine mustbe turned off and cool before refueling.Use proper refueling procedures andequipment to avoid spillage. Do not runengine near open fuel containers.Always store fuel in properly markedcontainers. DO NOT SMOKE.a.Be sure fuel tank has sufficient fuel.b.With engine level, check oil level. remove oildipstick (1) and wipe with a lint free cloth. Insert oildipstick all the way into the engine. Withdraw dipstick.Engine oil should coat oil dipstick to top mark (2).4-3