TM 10-4320-309-14
TM 4320-14/1
INDEX
Para
Para
Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Preparation for Movement . . . . . . . . . . . . . . . . 2-10
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Identification and lnformation
Preparation for Use . . . . . . . . . . . . . . . . . . . . . . 2-8
Nameplates . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Operating Procedures . . . . . . . . . . . . . . . . . . . 2-9
2-6. SCOPE
This section provides step-by-step instructions for all actions necessary to operate the equipment.
2-7. INSTALLATION (Refer to Figure 2-2)
a.
b.
c.
d.
The centrifugal pump unit is shipped in a cleated plywood box which is easily disassembled.
(1) Cut loose the three steel straps holding the box together.
(2) Remove the top cover.
(3) Remove the four sides in one piece.
(4) Loosen the four J-bolts and remove the centrifugal pump from the skid bottom.
Inspect the pump for dirt, grease, chipped paint, scratches, or dents.
If damage has occurred during shipment or transportation, report the damage on DD Form 6. Request
Direct Support Maintenance to refurbish, repaint, or repair the pump assembly.
The discharge and suction extensions are shipped loose and need to be installed before operating
pump.
Table 2-2. Installation Items
ITEM
DESCRIPTION
QUANTITY
1. Water
2 X 6 inch long brass nipple
2
2. Water
2 inch brass adapter
2
3. Water
2 inch FPT x 2 inch MPT brass elbow
1
4. Fuel
2 inch female quick disconnect coupling
1
5. Fuel
2 inch male quick disconnect coupling
1
(1) Items that require installation before pump is ready for operation are listed in Table 2-2
(2) Install one 2 x 6 inch long nipple (1) into the pump suction port. Install the other 2 x 6 inch long nip-
ple (1.) into the pump discharge port.
(3) Install one 2 inch adapter (2) onto the 6 inch nipple (1) in the pump suction port. Install the 2 inch
elbow (3.) onto the 6 inch nipple (1) in the pump discharge port.
2-25
Section III. OPERATION UNDER USUAL CONDITIONS