TM 10-4320-307-243-40SKIDREPAIR/REPLACE(CONT).CLEANING/INSPECTION/REPAIR :Live steam used for cleaning shall not exceed 100 psi (690 kPa). During steamcleaning operations, adequate ventilation, natural or forced, should be provided.Do not direct live steam against skin.Death or serious injury could occur if compressed air is directed against the skin.Do not use compressed air for cleaning or drying unless the pressure is/has beenreduced to 30 psi (2.11 kgcm2) or less. When working with compressed air alwaysuse chip guards, eye protection. and other personal protective equipment.1.Steam clean the skid and dry with compressed air.2.Inspect the skid for major bending and twisting. If frame straightening equipment is required, contact general supportmaintenance.3.If skid has no major bending and twisting. inspect for the following:a.Dents and localized bendingb.Torn or gouged areasc. Rust spots and puncturesd.Cracks in structure or weldse.Torn or distorted mounting holes4.Straighten out any dents or localized bending.Welding operations produce heat, highly toxic fumes. injurious radiation, metalslag, and airborne particles. Welding goggles, properly tinted lenses, an apron orjacket, and welders' boots are required to avoid injury to personnel.5. Weld cracks in structure or welds and use patches to repair areas that are rusted through or punctured. Refer to TM 9-237.Grinding operations create airborne dust and particles. Respiratory and eyeprotection is required to avoid injury to personnel.6.Grind smooth any gouges, tears, or repaired areas. Finish with emery cloth and repaint.3-157