TM 10-4320-307-24
3-31
LUBRICATING OIL PUMP/INSPECT/REPLACE CONT ).
NOTE
If drive shaft end clearance is not within specifications or further maintenance of
the lubricating oil pump is required, contact general support maintenance.
INSTALLATION:
1.
Install lube oil pump mounting flange gasket and cover. Tighten capscrews to 20 ft-lbs (25 Nm) torque.
2.
Install new gasket on body of lubricating oil pump.
3.
Install lubricating oil pump in mounting hole in cylinder block flange.
4.
Install five mounting capscrews and lockwashers. Tighten capscrews to 40 ft-lbs (55 N
m) torque.
5.
Install lubricating oil transfer tube using capscrews.
6.
Install pressure sensing line and tighten nuts to 120 in-lbs (15 N
m) torque.
7.
Install oil transfer tube in accordance with paragraph 3-38.
8.
Fill engine oil in accordance with paragraph 2-36.
OPERATIONAL CHECK:
Touching exhaust system during test can cause severe burns.
CARBON MONOXIDE (EXHAUST GAS) CAN KILL YOU
Exposure to exhaust gases produces symptoms of headache, dizziness,
loss of muscular control, drowsiness, or coma. Brain damage or death can
result from severe exposure.
Fumes from engine become concentrated with poor ventilation. Operate
engine in a ventilated area only.
While running engine, be alert for fumes. If someone is overcome, expose
to fresh air; keep warm and still: give artificial respiration if needed. Seek
medical attention. Administer oxygen, if available.
GOOD VENTILATION IS THE BEST DEFENSE AGAINST EXHAUST
POISONING.
1.
Start engine in accordance with TM 10-4320-307-10.
2.
Operate engine until water temperature reaches 180°F (80°C). Check oil pressure and check for oil leaks.
3-105