TM 10-4320-307-242-60INTERMEDIATETERMSTORAGE(Morethan30days ).The following instructions apply when the pumpingassembly is to be placed in storage for a period greater than 30 days. Additional or supplementary measures may bedirected to meet current or anticipated conditions such as extremes of temperature; exposure to dust, sand, or debris; orsalt air such as in a beachhead location. These instructions do not apply to temporary shutdowns to relocate the pumpingassembly.NOTEProcedure a., below, must be done with the assistance of direct support maintenance personnel.a.Prepare engine crankcase for storage:NOTEThe following procedures are most effective when initiated as quickly as possible after thepumping assembly has been taken out of service with the engine still at or near nor- maloperating temperatures.(1) Turn 2-way drain valve (1) to open position.(2) Once oil is drained, close 2-way valve (1).(3) Replace oil filters in accordance with paragraph 2-52.(4) Fill crankcase with clean lubricating oil.2-231