TM 10-4320-307-24
2-56 SUCTION AND DISCHARGE COVER REPAIR,'REPLACE.
This task covers:
a. Removal
b. Cleaning/lnspection/Repair
c. Installation
INITIAL SETUP
Tools
Personnel Required
Tool kit, general mechanic's (item 1, Appendix B)
Two
Materials/'Parts
General Safety Instructions
Area must be well ventilated.
Dry cleaning solvent (Item 30, Appendix C)
No open flame, sparks, or smoking while
using cleaning solvent
Emery cloth (Item 2, Appendix C)
.
REMOVAL:
NOTE
The removal of the suction and discharge
nozzle adapters are identical. Only the
discharge nozzle removal is presented.
1.
Remove 12 screws (1), washers (2), and nuts (3) that
secure discharge nozzle adapter (4) and gasket (5) to
pump discharge flange (6).
2.
Remove four screws (7) and washers (8) that secure
neck and pipe (9) to mounting plate (10) on skid.
3.
If nozzle adapter is not to be installed immediately,
install blind flange on discharge flange (6).
2-226