TM 10-4320-226-145.5.7 Injection Nozzle Maintenance.This task covers:5.5.7.1 Removal5.5.7.3 Installation5.5.7.2 RepairINITIALSETUPToolsGeneral Mechanics Tool Kit (appendix B,Section III, Item 1)Injector Pump Tester gauge (appendix B,Section III, Item 9)Equipment ConditionsEquipment shut down, refer toparagraph 2.5.1.2 or 2.5.2.2.Injection nozzle removed,GeneralInstructionsTo prevent rolling ornot work on equipmentsecurely stabilized.sliding, dothat is notDo not smoke or use open flamesaround fuel.Ensure container isused to catch fuel and fuel isdisposed of properly.Do not work on equipment withoutfollowing standard shop safetyprecautions.paragraph 5.5.3 step a.Figure 5-7.Injection NoZzle Maintenance.To prevent rolling or sliding, do not work on equipment that is notsecurely stabilized.Ensure both wheels are secure.Do not smoke or use open flames around fuel.Ensure container is used tocatch fuel and fuel is disposed of properly.Failure to obey these warnings may result in personal injury or death.5.5.7.1 Removal.a.Unscrew cap (figure 5-7, 1) and remove body (2), needle (3), and intermediatepiece (4).5-21