TM 10-4320-226-14a.b.Do not work on equipment that is operating.DO not touch exhaust system after equipment operation.Exhaustsystems become very hot and can cause serious burns.Failure to obey this warning could result in personal injury.If equipment is operating, shut down engineRefer to figure 4-15 and connect multimeter(paragraph 2.5.1.2 or 2.5.2.2).as follows:Doto(1)(2)not position test equipment in path of moving parts of engine.Failureobey this caution may result in equipment damage.Connect positive lead of multimeter to Positive Output (largest terminal) ofalternator.Connect negative lead of multimeter to ground.c.Ensure that leads of multimeter are not around moving parts and that leads aresecure on alternator terminals.Do not operate the 350 GPM Pumping Assembly without fuel source anddestinations connected.Failure to obey this caution may result inequipment damage.d.Refer to paragraphe.Observe multimeterf.Refer to paragraph2.5.1 and start enginereading.Reading must2.5.1.2 or 2.5.2.2 anduntil 2000 RPM is achieved.be between 13.8 and 14.8 V dc.stop engine.g.Disconnect multimeter from alternator terminals.h.When reading is not between 13.8 and 14.8 V dc, refer to paragraph 4.10.12 andreplace alternator.4-34