TM 10-4320-226-14
4.10.10 V-belt Contact Switch Maintenance.
This task covers:
4.10.10.1 Removal
4.10.10.2 Installation
INITIAL SETUP
Tools
General Mechanics Tool
Section III, item 1)
Material/Parts
Equipment Conditions
Kit (appendix B,
Equipment shut down,
(paragraph 2.5.1.2 or 2.5.2.2).
Cooling fan V-belt removed
(paragraph 4.10.8)
Tags (appendix E, Section II, Item 12)
General Safety Instructions
Do not work on equipment without
following standard shop safety
precautions.
Figure 4-14.
V-Belt Contact Switch Replacemnent.
4.10.10.1 Removal.
a.
Loosen nut (figure 4-14, 1) securing boot (2), and slide UP harness.
b.
Tag and disconnect wires (3) from V-belt contact switch (4).
c.
Remove nut (5) and V-belt contact switch (4) from bracket (6).
4.10.10.2 Installation.
a.
b.
4-32
Position V-belt
tighten.
contact switch (4) to bracket (6) and install nut (5), then
Wires must be connected to direct opposite terminals of V-belt contact
switch.
Connect wires (3) to V-belt contact switch (4), slide boot (2) down harness
and secure with nut (1).