Figure 2. Lower Control Panel
Figure 3. Fuel Shutoff Lever

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  102    103    104    105    106  107  108    109    110    111    112  
img
TM 5-3820-276-10-1
0011
Table 2.
Lower Control Panel - Continued.
Key
Control/Indicator
Function
6.
ELECTRODE
Used to connect electrode cable to welder/generator.
Terminal
7.
120 Volt
Used to supply (RC3) 60-Hz single-phase power at weld/power speed.
Receptacle (RC2)
Maximum output from (RC3) is 2.4 kVA/kW.
8.
120 Volt
Used to supply (RC2) 60-Hz single-phase power at weld/power speed.
Receptacle (RC3)
Maximum output from (RC2) is 2.4 kVA/kW.
9.
50 A MAIN
Protects (RC1), (RC2), and (RC3) from overload with a 50 amp circuit
BREAKER ON/OFF
breaker. If (CB1) opens, the receptacles will not work.
(CB1)
0011-4