TM5-4930-230-13
a.
Removal.
(1) Close dispensing valves on tanks by setting cam levers to CLOSE position.
(2) Open nozzles and drain hoses into a suitable container.
(3) Remove nozzles by pulling out on cam arms and disconnect couplings. (Figure 4-13.)
b. Cleaning and Inspection.
WARNING
Drycleaning solvent, P-D-680, used to clean parts is potentially dangerous
to personnel and property. Avoid repeated and prolonged skin contact. Do
not use near open flame or excessive heat. Flash point of solvent is 10O°F
to 138°F (38°C to 59°C).
Figure 4-13. Fuel Dispensing Nozzle Assembly.
4-30