TM5-4930-230-13a.Removal.(1) Close dispensing valves on tanks by setting cam levers to CLOSE position.(2) Open nozzles and drain hoses into a suitable container.(3) Remove nozzles by pulling out on cam arms and disconnect couplings. (Figure 4-13.)b. Cleaning and Inspection.WARNINGDrycleaning solvent, P-D-680, used to clean parts is potentially dangerousto personnel and property. Avoid repeated and prolonged skin contact. Donot use near open flame or excessive heat. Flash point of solvent is 10O°Fto 138°F (38°C to 59°C).Figure 4-13. Fuel Dispensing Nozzle Assembly.4-30