TM 5-4320-306-10
Table 2-1. Operator's Controls and Indicators - Continued
Key
Control or Indicator
Function
9
STARTER switch
Starts engine. When pushed to the STARTER position,
allows electric current to flow to the starter motor. This
switch is spring loaded to return to the down position when
released.
10
START/STOP switch
Energizes and deenergizes the pump and engine control
and operating circuits. This switch must be in the START
position before pressing the STARTER switch.
11
OIL BYPASS switch
Bypasses the low oil pressure switch. When starting the
engine, there is no oil pressure in the lubrication system,
and the low oil pressure switch would automatically shut
down the engine. Pressing the OIL BYPASS switch allows
the oil pressure to reach operating pressure during starting.
This switch must be pressed before pressing the STARTER
switch, and held in during starting.
12
Panel lights
Illuminate when turned on with PANEL LIGHTS switch (6).
Can be set to bright or dim.
13
MANUAL THROTTLE
Used to adjust engine speed and pump discharge pressure.
CONTROL
2-3