TM 5-4320-306-10
3-8. REPLACING AIR CLEANER PRIMARY AND SECONDARY ELEMENTS (Continued)
CAUTION
Hand tighten nut assembly as necessary to make a tight, vibration-free installation.
Overtightening the nut will deform the element.
13 Install nut assembly (4) and hand tighten.
14 Install baffle assembly (3).
15 Install cup assembly (2).
NOTE
Install cup assembly with arrows pointing up.
16 Seat cup assembly against body assembly (8).
CAUTION
Hand tighten clamp assembly as necessary to make a tight, vibration-free installation.
Overtightening the clamp assembly will deform the cup assembly or the body assembly.
17 Hand tighten clamp assembly (1).
18 Reset air cleaner intake restriction indicator (9).
3-16