TM 5-4320-302-14
5-21.
VALVES, VALVE GUIDES, AND VALVE SEATS (CONT)
Location/Item
Action
Remarks
3.
Valve cones, spring caps,
Remove from cylinder head.
compression springs,
valve rotators, inlet
valve, and exhaust
valve
CLEANING/INSPECTION
OF VALVES
WARNING
Dry cleaning solvent is flammable and potentially
dangerous to people and property. Do not use near
open flame, sparks, excessive heat, or on hot surfaces.
Flash point of P-D-680 solvent is 100° to 138°F (38° to
59°C). Use solvent in a well-ventilated area, and avoid
inhaling fumes. If repeatedly exposed to fumes, seek
fresh air and immediate medical help. Avoid prolonged
exposure of skin to solvent. Wash exposed skin
immediately and thoroughly. Death or severe injury
might result when compressed air is used to blow dirt
from skin or clothing. Air entering body openings is
extremely dangerous. Compressed air used for
cleaning shall not exceed 100 psi (690 kPa). Use
goggles or face shield for eye protection. Do not direct
airstream against skin.
4.
All valve
Clean with P-D-680 dry cleaning solvent and
components
dry with compressed air.
5-95