TM 5-4320-302-145-17.COOLING AIR BLOWER (CONT)Location/ItemActionRemarksCLEANINGWARNINGSevere burns, illness, or death may result if personnel fail to handle diesel fuel oil properly. Observe the following precautions:Do not inhale vapor.Do not handle near open flame, sparks, orexcessive heat.Work in a well-ventilated area.7All partsWash with clean VV-F-800 diesel fuel oil. If necessary,scrub with soft-bristled brush. Allow parts to air dry.INSPECTION8.AssembledInspect assembly for evidence of corrosion on matingquill shaftsurfaces. If corrosion is evident, mark location of bushand bushon quill shaft, and press quill shaft out of bush. Inspectinside diameter of bush and outside diameter of quillshaft for corrosion and/or damage that would preventreuse of parts. If no corrosion is evident at matingsurfaces of bush and quill shaft, inspect all exposedsurfaces for corrosion and/or physical damage thatwould prevent reuse of components. Be sure quill shaftis straight. Replace bent quill shaft.9.V-belt pulleya.Check hex bolt and hex nut threads for cross-threading, damage, and/or corrosion that wouldprevent reuse. Replace damaged hex bolt orhexnut.b.Check pulley sheaves for sharp edges and/orcorrosion or damage that could damage V-beltsduring operation.10. Bottom rollerCheck blades of roller for indications that roller has beenrubbing on blower jacket. Physical damage to rollerblades could indicate damaged blower jacket or bentquill shaft. Check surface of roller and inside diameterof the bore into which the quill shaft is installed forcorrosion or damage.5-50