INTERVALTM 5-4320-302-14Table 2-2. Operator/Crew Preventive Maintenance Checks and Services-ContinuedBBEFORE OPERATIONDDURING OPERATIONAAFTER OPERATIONWWEEKLYMMONTHLYBDAWM2Control Panel Cover Assembly Controls, Meters, Gages,Oil pressure isand Indicators.below 20 psig(137.9 kPa) orCheck for broken lenses and indications of proper opera-air cleaner re-tion. Readings or indications during operation shall fallstriction indi-within the ranges given below:cator showsred.2-inch switchgage-Oil pressure must be 60 psig to80 psig (413.7 kPa to 551.6 kPa). No evidence ofleakage.Air cleaner restriction indicator-No red flag inwindow of indicator. No evidence of leakage.Tachometer-2750 rpm to 2950 rpm. Hourmeterrecording elapsed time.Ammeter-Charging rate 0 to 60 amps maximum.Check for smooth operation when using throttle cableassembly and priming cable assembly.ITEMNO.ITEM TO BE INSPECTEDPROCEDURE: CHECK FOR AND HAVE REPAIRED,FILLED, OR ADJUSTED AS NEEDEDEQUIPMENT IS NOTREADY/AVAILABLE IF:2-9