TM 5-4320-302-144-30.COOLING AIR BLOWER AND COOLING AIR DUCTING (CONT)Location/ItemActionRemarksCAUTIONPrime the centrifugal pump as soon as possible after engine starts. Rotation ofimpeller without water in volute will damage pump components.24.EngineStart engine and check for loose, rattling compo-nents. Tighten as necessary to prevent rattles.Check for fuel leaks around injection lines andfuel vent. Tighten connections as necessary. Checkfor positive deflection of ammeter. If ammetershows a negative current flow, check electricalsystem (paragraph 4-15) or ammeter (paragraph4-16). Shut down engine.4-148