Home
Download PDF
Order CD-ROM
Order in Print
TEST - TM-5-4320-302-14_200
AIR CLEANER, AIR INTAKE TUBES, ELB OWS, AND RAIN CAP (CONT) - TM-5-4320-302-14_202
TM-5-4320-302-14 Forward Area Water Point Supply System (FAWPSS) Model WP55100 NSN 4320-01-168-1629 and Model 9095-91 NSN 4320-01-338-3305 Manual
Page Navigation
188
189
190
191
192
193
194
195
196
197
198
TM 5-4320-302-14
4-21.
AIR CLEANER
, AIR INTAKE TUBES, ELBOWS, AND RAIN CAP
This task covers:
a.
Removal
d.
Installation/Replacement
b.
Inspection
e.
Test System
c.
Repair
INITIAL SETUP
Tools
References
Tool kit, general mechanics automotive
Para 4-16 Control Panel
Cover Assembly
,
NSN
5180-00-177-7033
Control Panel Assembly
, Instruments, and Switches
Materials/Parts
MIL-T-704 Treatment and Painting of Materiel
Air cleaner
Troubleshooting References (Table 4-2)
Air cleaner mounting brackets
Malfunction 2, step 3
Air cleaner
service indicator hose assembly
Malfunction 3, step 1
Air intake tubes, elbows, hoses, clamps,
and adapters
Special
Environmental Conditions
Rain cap
Adequate ventilation required during cleaning
Materials required by MIL-T-704
and testing.
Location/Item
Action
Remarks
REMOVAL
1.
Air cleaner
Loosen hose clamp and
remove hose
from
service indicator
elbow.
hose
2.
Elbow
Remove.
3.
Lower air
Loosen two hose clamps and remove lower
inlet elbow
air inlet elbow.
4-105
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business