TM 5-4320-300-14Table 3-1. Operator/Crew Troubleshooting-ContinuedMALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION2.ENGINE CRANKS BUT FAILS TO STARTWARNINGSevere burns, illness, or death may result if personnel fail to handle diesel fuel properly. Observethe following precautions:·Do not inhale vapor.·Do not refuel near open flame, sparks, or excessive heat.·Be certain fuel lines and connections are secure.·Do not overfill fuel tank.·Work in a well-ventilated area.Step 1. Check for insufficient fuel supply.Refill low tank. If empty, notify organizational maintenance.Step 2. Check for proper operation of starting aid.If starting aid is not working properly, notify organizational maintenance.3-2