TM 5-4320-300-14WARNINGCompressed air used for cleaning shall not exceed 100 psi (690 kPa). Use goggles or face shieldfor eye protection. Do not direct airstream against skin.(4)If a regulated compressed air supply is available, direct a stream of compressed air (100 psi (690 kPa) maximum) through the element from the inside.CAUTIONDo not blow out body assembly with compressed air. Equipment damage could result if dust isnot removed from body assembly with damp cloth.(5)Reassemble air cleaner by replacing baffle assembly in cup assembly. Carefully insert filter element inbody assembly and tighten wing nut securely. Reinstall cup assembly to body assembly making certaincup assembly seals completely around air cleaner body. Position clamp assembly and tighten wing nut.Reset restriction indicator by pushing down button on top of indicator.WARNINGSevere burns, illness, or death may result if personnel fail to handle diesel fuel properly. Observethe following precautions:·Do not inhale vapor.·Do not refuel near open flame, sparks, or excessive heat.·Be certain fuel lines and connections are secure.·Do not overfill fuel tank.·Work in a well-ventilated area.b.While filling fuel tank, take care to prevent sand and dust from entering fuel system.2-63