TM 5-4320-300-14
4-34. LOW OIL PRESSURE CUTOUT SWITCH
This task covers:
a.
Test
b.
Removal
c.
Installation
INITIAL SETUP :
Test Equipment
General Safety Instructions
Multimeter
WARNING
Tools
Tool kit, general mechanics automotive
Exposure to exhaust gases produces symp-
NSN 5180-00-177-7033
toms of headache, dizziness, loss of muscu-
lar control, drowsiness, or coma. Brain
Shop equipment, automotive maintenance
damage or death can result from severe
and repair, common no. 1
exposure.
NSN 4910-00-734-0654
Fumes from engines become concentrated
Materials/Parts
with poor ventilation .
Low oil pressure cutout switch
1.
Operate engine in a ventilated area only.
Personnel Required: 2
2.
Ventilate personnel compartments when
idling engine.
Mechanic will crank engine and read oil
pressure gage.
3.
While running vehicle, be alert for
fumes. Keep compartments ventilated.
Equipment Condition
If someone is overcome, expose to fresh
air; keep warm and still, give artificial
Engine left side panel removed.
respiration if needed. Seek medical atten-
tion. Administer oxygen, if available .
Special Environmental Conditions
GOOD VENTILATION IS THE BEST DE -
Well-ventilated area required.
FENSE AGAINST EXHAUST POISONING .
4-138