TM 5-4320-300-144-25. AIR SHUTDOWN SOLENOID (CONT)Location/ItemActionRemarksREPLACEMENT4. SolenoidSupport replacement solenoid and installmounting bolts in mounting bracket.Tighten securely.5. Solenoid con-Reconnect tagged connecting wires tonecting wiressolenoid terminal nuts. Tighten securely.6. Control rodScrew upper adjustment nut as far as it willgo on control rod of replacement solenoid,then remove lower adjustment nut. Installlink onto control rod. Reinstall lower ad-justment nut and tighten securely.NOTELink should now be positioned on control rod of replacement solenoid in same position as oncontrol rod of replaced solenoid. If rough operation occurs, it may be necessary to raise or lowerthe link on the control rod with the upper and lower adjustment nuts.4-115