TM 5-4320-300-14
1-11.
IDENTIFICATION
The centrifugal pump has the following identification and instruction plates:
a.
Identification plate. The identification plate is located on front of
the pump above the suction flange. It provides the pump identification
number, serial number, dimensions, weight, and shipping information.
b.
Instruction plate. The instruction plate is located in the control
panel cover. It provides necessary cautions for starting the centrifugal
pump, step-by-step procedures for starting engine, and shutdown
procedures.
c.
Suction plate. Identifies suction port of pump.
d.
Discharge plate. Identifies discharge port of pump.
1-12.
DIFFERENCES BETWEEN MODELS
This technical manual covers only Centrifugal Pump Unit, Peabody
Barnes Model US90CCD-1, part number 72121CA. No known differences exist for this model number.
1-13.
EQUIPMENT DATA
a.
Pump.
Manufacturer.................................................................................................................................. Peabody Barnes, Inc.
Part number ...................................................................................................................................................... 57057SA
Type .......................................................................................................................................... Self-priming centrifugal
Service ..................................................................................................................................................................Water
Duty cycle ......................................................................................................................................................Continuous
Rated output ........................................................................................................................... 1500 gpm at 60 foot head
Suction port....................................................................................................................................................6-inch NPT
Discharge port................................................................................................................................................6-inch NPT
Priming port ...................................................................................................................................................2-inch NPT
Drain port . ...............................................................................................................................................1-1/2-inch NPT
Rotation ................................................................................................................. Counterclockwise (facing pump inlet)
1-5