PUMP - Continued
ACCUMULATOR AND DISCHARGE PORT - Continued

Maintenance Manual, Pump, Reciprocating, Power-Driven, Diaphragm, Gas-Engine-Driven, Wheel-Mounted Page Navigation
  111    112    113    114    115  116  117    118    119    120    121  
img
. . . .
TM 5-4320-275-13 & P
5-9. ACCUMULATOR AND DISCHARGE PORT
This task covers:
Thread repair.
INITIAL SETUP
References
None
Test equipment
None
Troubleshooting References
Tools
None
Shop equipment, automotive
maintenance and repair
Equipment Condition
NSN 4910-00-754-0654
Tap, 2 inch NPT, and handle
Accumulator and discharge port
Tap, 4 inch NPT, and handle
removed from pump assembly.
Materials/Parts
Special Environmental Conditions
Accumulator (Appendix C, item 5, fig. 6)
None
Discharge port (Appendix C, item 9, fig. 6)
General Safety instructions
Personnel Required: 2
Compressed air for cleaning shall not exceed
Mechanic will assist in lifting accumulator.
30 psi (207 kPa). Use goggles or face shield
to prevent eye injury from flying chips.
5-8