TM 5-4320-275-13 & P
CLAMP ASSEMBLY (CONT)
LOCATION/ITEM
ACTION
REMARKS
DISASSEMBLY
1. Studs
Use 1/2 inch stud removing and installing
tool to remove studs (1): from con-
necting rod clamp (2).
INSPECTION
2. Threads
Inspect threads on studs. (1) and threads in con-
necting rod clamp (2) for damage. Replace
damaged parts.
3. Connecting
Inspect connecting rod clamp (2) for cracks or
rod clamp
warpage. Replace if damaged.
CLEANING
WARNING
Clean parts in a well-ventilated area. Avoid inhalation of solvent fumes and prolonged
exposure. of skin to cleaning solvent. Wash exposed skin thoroughly. Dry cleaning solvent
(fed spec P-D,680) used to clean parts is potentially dangerous to personnel and property. Do
not use near open flame or excessive heat. Flash point of solvent is 100F (38C).
4. Studs and
Clean studs and connecting rod clamp with
connecting
cleaning solvent, P-D-680. Use a stiff-bristle
rod clamp
brush to remove caked dirt.
4-66