Section VII. MAINTENANCE OF PUMP
Figure 4-4. Electric motor assembly, removal and installation.

Maintenance Manual Pump, Centrifugal: Frame Mounted, 1 1/2 In. Mil-P-14514D, Electrical Motor Driven Page Navigation
  14    15    16    17    18  19  20    21    22    23    24  
img
TM 5-4320-274-14&P
Step 1. REMOVE COVER PLATE AND PREFORMED
Step 2. REMOVE THE IMPELLER.
PACKING
Figure 4-3. Centrifugal pump assembly, removal and installation.
(2) Position wear plate on pump and secure with the wear plate retaining screws. Install shims as required to
maintain wear plate-to-impeller clearance of 0.010-0.015 in.
(3) Loosen peeler adjustment setscrew. Position impeller on shaft adapter with the adapter key. Adjust
setscrew to obtain peeler-to-impeller clearance of 0.005-0.015 in. Secure impeller with impeller cap screw.
4-9