TM 5-4320-274-14&P
Section II. MOVEMENT TO A NEW WORKSITE
4-4. Dismantling for Movement
a. Disconnect the hose lines from the flange adapters.
b. Cover the suction and discharge flange adapters to protect the threads and prevent foreign matter from entering
the pump.
c. Disconnect the ground lead from terminal lug (fig. 4-2).
4-5. Reinstallation After Movement
Section III. REPAIR PARTS, SPECIAL TOOLS, AND EQUIPMENT
4-6. Tools and Equipment
a. Basic tools and repair parts issued with, or
authorized for the pumping unit are listed in
Appendix C of
this
manual.
b. No special tools or equipment are required by organizational personnel for maintenance of the pumping unit.
4-7. Organizational Maintenance Repair Parts
Repair parts and equipment are listed and illustrated in the repair parts and special tools list covering organizational
maintenance for this equipment in Appendix C of this manual.
Section IV. LUBRICATION INSTRUCTIONS
4.8 The electric motor powered pump has been pre- lubricated at the factory and requires no specific lubrication.
Section V. PREVENTIVE MAINTENANCE CHECKS AND SERVICES
4-9. General
To insure -that the pumping units are ready for operation at all times, they must be systematically inspected so that
defects may be discovered and corrected before they result in serious damage or failure. The necessary preventive
maintenance checks and services to be performed are listed in paragraph 4-10. All deficiencies and shortcomings will be
recorded together with the corrective action taken on DA Form 2404 (Equipment Inspection and Maintenance
Worksheet).
4-10. Preventive Maintenance Checks and Services
Refer to table 4-1 for the applicable preventive maintenance checks and services.
4-4