TM 5-4320-200-13&PItemNo.5IntervalBeforeTable 2-1 Operator Preventive Maintenance Checks and ServicesLocationItem to Check/ServiceENGINEProcedureCaution use care when cleaning. donot puncture filter element. Pressbutton (14) in SERVICE LEVEL sig-nal.Perform lubrication to or in conjunc-tion with with PMCS.Refer to LO 5-2805-256-16.Make the following walk aroundchecks;a. Check for fuel leakage on aroundand under pump assembly.b. Check air cleaner restriction indi-cator if red RED SERVICE signal isvisible, clean or replace filter element.c. Check for broken, cracked, anddamaged motor mounts and compo-nents. Check for loose and missinghardware. Check frame and shockmounts for deterioration, cracks, anddamage.Not Fully MissionCapableClass III oil leaks orany fuel leaks found.Motor mounts, shockmounts, components,or hardware missing,damaged cracked ordeteriorated.Change 52-8.1