0085
SERVICE - Continued
WARNING
Compressed air used for cleaning and drying purposes must not exceed 30 psi (207 kPa).
Use only with effective chip guarding and proper protective equipment (goggles, shield,
gloves, etc.). Failure to comply may result in injury or death to personnel.
2.
Clean air filter element (Figure 3, Item 1) using only light brushing, or mild compressed air.
CAUTION
Do not remove inner air filter element. Failure to comply may result in damage to
equipment.
Do not use compressed air to clean air filter housing. Contaminants could enter engine.
Failure to comply may result in damage to equipment.
3.
Clean inside of air cleaner housing (Figure 4, Item 2) with a clean, damp rag to remove contaminants.
2
Figure 4. Air Filter Element Service.
END OF TASK
INSTALLATION
1.
Install outer air filter element (Figure 5, Item 5) in air cleaner housing (Figure 5, Item 2).