TM 5-3825-270-10
0012
CONNECT CAB CONTROL BOX TO CAB OF PRIME MOVER - Continued
3, 4
Figure 22. Connect Cab Control Box to Cab of Prime Mover.
3.
Remove cab control box harness cap (Figure 23, Item 5) from wire harness (Figure 23, Item 6).
5
6
Figure 23. Connect Cab Control Box to Cab of Prime Mover.
CAUTION
Cab control box harness is match marked for ease of connection. Ensure that cab control
box harness is aligned during connection. Failure to comply may cause damage to pins in
harness.
4.
Connect wire harness (Figure 24, Item 4) to connection point (Figure 24, Item 6).