• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 3. Engine and Transmission Compartment
Figure 5. WWSV Left-Side

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  389    390    391    392    393  394  395    396    397    398    399  
img
.
TM 5-3820-276-10-2
0199
Table 1.
PMCS - WWSV - Before Road and Towing Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
2
3
4
5
1
6
7
8
6
6
6
WWDS00751
Figure 4.
Air Tank Drain Valves and Circuit Breakers.
7
Before
Slave
Check slave receptacle (Figure 4, Item 8) for damage
Slave receptacle
Receptacle
or broken wires.
damaged or wires broken.
Notify maintenance.
8
Before
Stowage Box
Check stowage box (Figure 4, Item 7) for security,
Stowage box not secure,
missing hardware, or damage.
missing hardware, or
damaged. Notify
maintenance.
9
Before
Circuit Breakers
1. Check circuit breakers (Figure 4, Items 2 and 4) for
Circuit breaker damaged.
damage.
Notify maintenance.
2. Check circuit breaker ON/OFF levers (Figure 4,
Circuit breaker levers
Items 3 and 5) for damage.
loose, broken, or will not
turn on or off. Notify
maintenance. Ensure
circuit breaker levers are
set to ON position.
3. Check electrical cables (Figure 4, Item 6) for security Cables loose or
and damage.
damaged. Notify
maintenance.
0199-5
02/13/2013root(pmcswp)wpno(I20001)


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.