TM 5-3820-276-10-2
0198
Table 6.
PMCS - WWDR - After Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
damaged. Notify
maintenance.
4. Check upper hydraulic oil cooler fans (not shown) for Upper hydraulic oil cooler
broken fan guards, loose electrical connections,
fan guards damaged, fan
broken wires, missing hardware.
guards broken, electrical
connections loose, wires
broken, or missing
hardware or damage.
Notify maintenance.
3
After
Lower Hydraulic
1. Check lower hydraulic oil cooler (Figure 44, Item 1)
Lower oil cooler fins
Oil Cooler
for clogged and damaged fins.
clogged or damaged.
Notify maintenance.
1
2
WWDS00623
Figure 44. Lower Hydraulic Oil Cooler.
2. Check lower hydraulic oil cooler for damage, missing Lower hydraulic oil cooler
hardware, loose hoses, or leaks.
damaged, missing
hardware, hoses loose or
leaking. Notify
maintenance.
3. Check lower hydraulic oil cooler temperature gauge
Lower hydraulic oil cooler
(Figure 44, Item 2) for damage.
temperature gauge
damaged. Notify
maintenance.
4. Check lower hydraulic oil cooler fans (not shown)
Hydraulic oil cooler fan
for damage, broken fan guards, loose electrical
damaged, guards broken,
connections, broken wires, or missing hardware.
loose electrical
connections, broken
wires, or missing
hardware. Notify
maintenance.
02/13/2013root(pmcswp)wpno(I10001)