NO ELECTRICAL CIRCUITS OPERATE - WATER WELL DRILLING RIG (WWDR)
NO ELECTRICAL CIRCUITS OPERATE - WWDR - Continued

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  44    45    46    47    48  49  50    51    52    53    54  
img
. .
TM 5-3820-276-10-2
0095
NO ELECTRICAL CIRCUITS OPERATE - WWDR - Continued
MALFUNCTION
150A circuit breaker wiring loose, damaged, or corroded.
CORRECTIVE ACTION
Visually inspect if wiring at 150A circuit breaker is loose, damaged, or corroded (Figure 2).
150A
CIRCUIT BREAKER
WIRING
WWDS01037
Figure 2.
Circuit Breaker (150A) Wiring.
a.
If wiring at 150A circuit breaker is loose, damaged, or corroded, notify maintenance.
b.
If wiring at 150A circuit breaker is not loose, damaged, or corroded, proceed to next
MALFUNCTION - Loose, damaged, or corroded battery terminals.
MALFUNCTION
Loose, damaged, or corroded battery terminals.
CORRECTIVE ACTION
WARNING
DO NOT allow battery acid to contact eyes, skin, or fabric. Upon contact with
eyes or skin, immediately flush with water, apply first aid and obtain medical
attention. DO NOT lean over battery when connecting or disconnecting battery
cables. DO NOT allow negative and positive cables to touch each other. Keep
open flame or sparks away from battery vent holes. ALWAYS wear eye
protection when working with batteries. Failure to comply may result in injury or
death to personnel. Seek medical attention in the event of an injury.
Remove battery box cover (WP 0198) and visually inspect battery terminals for damage,
corrosion, or loose connections (Figure 3).
0095-2