TM 10-4630-207-13&P
0032 00
If the isolation valve handle and linkage must be replaced, proceed as follows:
1. Remove the pin assembly (figure 7 item 1) from the handle rod (figure 7 item 2).
2. Disconnect the swivel assembly (figure 7 item 3) from isolation valve handle (figure 7 item 4).
3. Remove the swivel assembly (figure 7 item 3) from the handle rod (figure 7 item 2).
4. Remove the handle rod (figure 7 item 2) by pulling it through the guide (figure 7 item 5).
5. Remove the lock and adjusting nut (figure 7 item 6) from the handle rod (figure 7 item 2).
6. Remove the isolation valve handle (figure 7 item 4) from the valve housing (figure 7 item 7).
7. Install new isolation valve handle.
8. Install isolation valve handle (figure 7 item 4) to the valve housing (figure 7 item 7).
9. Fasten and tighten lock and adjusting nut (figure 7 item 6) to the handle rod (figure 7 item 2).
10. Feed the handle rod (figure 7 item 2) through the guide (figure 7 item 5).
11. Fasten the swivel assembly (figure 7 item 3) to the handle rod (figure 7 item 2).
12. Connect the swivel assembly (figure 7 item 3) to the isolation valve handle (figure 7 item 4).
13. Connect the pin assembly (figure 7 item 1) to the handle rod (figure 7 item 2).
0032 00-5