TM 10-4630-207-13&P
0031 00
1
2
Figure 8. Installing Pressure Gage and Sight Glass
18. If the drain hose nipple (figure 9, item 1) needs to be replaced, remove and install a new nipple onto
the drain valve as shown below.
1
Figure 9. Drain Hose Nipple
19. Install the drain valve (figure 10, item 3) onto the bottom of the trap housing (figure 10, item 4).
20. Position the moisture trap onto the bracket (figure 11, item 1).
21. While supporting the moisture trap, install three hex bolts (figure 11, item 2), nuts (figure 11, item 3)
flat washers (figure 11, item 4) and lockwashers (figure 11, item 5) into the moisture trap mounting
bracket (figure 11, item 1).
22. Install the drain hose (figure 10, item 1) onto the drain hose nipple (figure 10, item 2).
0031 00-5