TM 10-4630-206-12&P
0022 00
REPLACE
Replace Check Valve (9-1-0150-1 and 9-1-0150-2)
WARNING
Ensure the SEP has been thoroughly cleaned with chlorine solution
and rinsed prior to any inspection or service to the interior. Failure
to do so may result in serious illness or death to personnel.
1. Remove tank lid.
2. Loosen hose clamps (1).
3. Remove discharge hose (2) from pump outlet and check valve (3).
4. Remove check valve from bushing (4).
5. Apply pipe sealant or antisieze tape to threads, and install new check valve to bushing.
6. Install discharge hose (2) to pump outlet and check valve (3).
7. Secure with hose clamps (1).
3
4
1
2
0022 00-5