TM 10-4320-344-10
Table 2-11.
Preventive Maintenance Checks and Services for Pumping Assembly
Model 609-C.
(Continued)
Location
Item
Item to
Not Fully Mis-
No.
Interval
Check/Service
Procedure
sion Capable if:
BATTERY BOX
43
44
Fumes from battery acid may cause explosion,
personal injury.
Keep sparks and open flame
which could result in
away from battery.
Battery electrolyte contains sulfuric acid, which can cause severe burns.
If electrolyte should contact skin or clothing, rinse immediately with
clean water.
After
A f t er
Battery Box
Batteries and
Battery Cables
Check for damage.
If damaged,
notify unit maintenance.
Unlatch and open battery box
cover.
Check cables for
corrosion, loose connections,
and damage.
Clean corrosion
and tighten connections as
required.
Check battery for
cracks or damage.
Remove
battery caps and check fluid
l e v e l.
If fluid level is low,
notify unit maintenance.
Install battery caps.
Close
and latch battery box cover.
Cracked battery.
Low fluid level.
Damaged battery
c a b l e .
2-60