4-29. MAINTENANCE OF VALVE COVER.
This task covers:
a. Remove
c. Install
b. Service
INITIAL SETUP
Tools
General Mechanics Tool Kit
(Item 1, Appendix B)
Parts/Materials
Gasket (TM 10-4320-318-24P)
Rags (Item 8, Appendix E)
Cleaning Solvent
(Item 9, Appendix E)
General Safety Instructions
WARNING
Solvent may cause toxic fumes. To prevent
personal injury, work only in well-ventilated area.
DO NOT breath fumes for a long time.
Solvent is flammable.
To prevent fire or
explosion, DO NOT bring open flame or sparks
near solvent.
Equipment Conditions
Pump unit is shut down (para.2-8).
Noise enclosure access doors are opened.
a.
REMOVE (Figure 4-16),
Figure 4-16. Valve Cover
(1) Loosen capscrew (1) and clamp (2) holding drain tube (3) to crankcase.