TM 10-4320-309-14
TM 4320-14/1
Item
No.
5
6
7
2-8
Table 2-1. Preventive Maintenance Checks and Services - Continued
Interval
Before
Before
Before
ITEM TO BE INSPECTED
PROCEDURES
CENTRIFUGAL PUMP ASSEMBLY
When draining, do not smoke or use open flame in the
area. Always make metal-to metal contact between
the container and the fuel hose. This will prevent a
spark as fuel flows over metallic surfaces Failure to
observe this warning may result in death to person-
nel.
NOTE
When pump is not in use, water should be drained.
Drain Plug
Check that pipe cap (1) is securely installed.
Check Valve
Look through suction port and check for damage to suc-
tion check valve (2).
Suction Piping
Visually check interior of suction port for foreign matter
that could enter into pump during operation.
Not Fully Mission
Capable If:
Drain plug is not prop-
erly installed. Notify
Unit Maintenance.
Suction check valve is
damaged. Notify Unit
Maintenance.
Suction line is dogged
with foreign matter.
Notify Unit Mainte-