TM 10-4320-309-14
TM 4320-14/1
Item
No.
1
2
3
4
Table 2-1. Preventive Maintenance Checks and Services- Continued
Interval
Before
Before
Before
Before
ITEM TO BE INSPECTED
PROCEDURES
Chemical Agent Resistant Coating (CARC)
Check condition of Chemical Agent Resistant Coating.
Coating shall be in good condition with no base metal or
corrosion.
Identification Plate
Check that identification plate (1) can be read.
Door Latch
Check that access door latch (2) and fastening hardware
(3) are secure.
Enclosure Acoustical Foam, Rivets, and Screws
Check condition of sound enclosure rivets (4) and self-
tapping screws (5).
Inspect acoustical foam within the enclosure. Check to
make sure acoustical foam does not block air flow, is not
torn or scarred, and does not show signs of contacting a
hot surface.
Not Fully Mission
Capable If:
Enclosure compo-
nents visibly sepa-
rated at rivet seams.
Notify Unit Mainte-
nance.
2-7