TM 10-4320-309-14TM 4320-14/1Figure 4-7. Replacing Impeller, Shaft Seal, and Shaft AdapterNOTEWhen replacing seal, also replace volute O-ring (refer to item 2,Figure 4-6), wear plate O-ring (8, Figure 4-7), and four self-sealingscrews (10).c.Install stationary rubber seat (9A) into pump casing cavity.d.Install new shaft seal (9) onto shaft adapter (12).e.If a new impeller and/or wear plate is installed or if the impeller clearance is to be changed, determinethe shim thickness required to obtain a clearance of 0.010 to 0.015 inch (0.254 to 0.381 mm) by thefollowing procedure:(1) Screw impeller (3) dockwise onto shaft adapter (12) without shims (4 and 5). Be sure that the impelleris seated firmly against the shaft shoulder. Secure the impeller with teflon washer (2) and hex bolt (1).4-21