TM 10-4320-307-24
2-27
BATTERIES, BATTERY BOX, AND BATTERY CABLE ASSEMBLY SERVICE/TEST/REPAIR/REPLACE
(CONT).
5.
Test battery charging receptacle (5) as follows:
a.
Tag positive charging cable (6), positive terminal (7), negative charging cable (8), and negative terminal (9).
b.
Remove screws (10) and lockwashers (11) that secure cables to terminals and place cables aside so that they
cannot touch each other or other terminals.
c.
Connect multimeter (12) positive lead (13) to positive terminal (7) of receptacle and negative lead (14) to
negative terminal (9) of receptacle.
d.
Connect charging cable (15) to charging receptacle (5) and apply charging power.
e.
Multimeter (12) reading should equal the charging voltage applied (approximately 24 volts). If reading is below
the required voltage, replace charging receptacle (5).
2-84