TM 10-4320-226-14Table 4-1. Preventive Maintenance Checks and Services for the 350 GPM Pumping Assembly.(continued)Not Fully MissionCapableIf:ItemNo.4567891011121314IntervalQuarterlyQuarterlyQuarterlyQuarterlyQuarterlyQuarterlyQuarterlyQuarterlyWHEELSQuarterlyAnnuallyAnnuallyItem tobe InspectedAIR CLEANERBATTERIESCheck to ensure battery is charged.V-BELTInspect V-belt for tightness. Make sure belt isnot cracked, broken, stretched, or damaged.V-BELT CONTACTTest switch to ensure it works properly.SWITCH(Paragraph 4.10.9)ENGINE VALVECheck engine valve clearance.CLEARANCE(Paragraph 4.10.23)CRANKCASE,BLOCKS ANDCYLINDER HEADInspect for cracks, or other damage. Cleanblock and cylinder head cooling fins.TIRESCheck for proper inflation, 40 psi (275.9 kPa).Measure tread depth using tread gauge atthree equally spaced points on tire (should bemore than 1/8 in,); inspect tires for cuts,cracks, or uneven wear.Check wheels and bearings for damage.Service bearings in accordance withLO 5-4320-226-12.AXLESHUTDOWNSOLENOIDVisually inspect all structural parts forexcessive wear, corrosion, broken welds,cracks, and security.Test solenoid to ensure it works properly.(Paragraph 4.10.14)ENGINE STARTReplace engine start cartride(ether can).CARTRIDE(Paragraph 4.10.3.1)ProcedureInspect for cracked, or damaged air cleaner.Check condition of fitter housing.(Paragraph 4.10.5)Air cleaner isdamaged ormissing.Battery does notmaintain charge.V-belt can not beadjusted to propertension.r/-belt switchdefective.Engine valveclearance can notbe met.Crankcase,blocks, andcylinder heads arenot serviceable.Tires are notserviceable.Wheels are notserviceable.Shutdownsolenoid isdefective.4-6 Change 2