TM 10-4320-226-14
SECTION III.
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES
4.7 GENERAL.
Figure 4-1 (PMCS routing diagram) and table 4-1 (PMCS table) have been provided so
you can keep your equipment in good operating condition and ready for its primary
mission.
4.7.1 Warnings, Cautions, and Notes.
Always observe the WARNING and CAUTIONS appearing
in your PMCS table.
Warnings and cautions appear before applicable procedures.
You must observe these WARNINGS and CAUTIONS to prevent serious injury to yourself
and others or prevent your equipment from being damaged.
4.7.2 Explanation of Table Entries.
4.7.2.1 Item No. column.
Numbers in this column are for reference.
When completing DA
Form 2404 (Equipment Inspection and Maintenance Worksheet), include the item number
for the check/service indicating a fault.
Item numbers also appear in the order
that you must do checks and services for the intervals listed.
These item numbers
also corresponds to the numbers on the routing diagram, figure 4-1.
4.7.2.2 Interval Column.
This column tells you when you must do the procedure in the
procedure column.
4.7.2.3 Item to be Inspected Column.
This column provides the item to be checked or
serviced.
4.7.2.4 Procedure Column.
This column gives the procedure you must do to check or
service the item listed in the Check/Service column to know if the equipment is
ready or available for its intended mission or for operation.
You must do the
procedure at the time stated in the interval column.
4.7.2.5 Not Fully Mission Capable if: Column.
Information in this column tells you what
faults will keep your equipment from performing its primary mission.
If you make
checks or service procedures that show faults listed in this column, do not operate
the equipment.
Follow standard operating procedures for maintaining the equipment
or reporting equipment failure.
4.7.3 Other Table Entries.
Be sure to observe all special information and notes that
appear in your table.
Item
No.
Change oil and oil filter in accordance with
LO 10-4320-226-12
1
2
3
Table 4-1.
Preventive Maintenance Checks and Services
for 350 GPM Pumping Assembly.
Interval
Item to be
Procedures
inspected
200 Hours
500 Hours
Quarterly
OIL FILTER
FUEL FILTER
SPARK ARRESTOR
Change oil and replace oil filter.
Replace fuel filter
(paragraph 4.10.18)
Remove and service spark arrestor
(paragraph 4.9.1).
Not Fully
Mission
Capable If:
Spark arrestor
is damaged or
missing.
4-5