TM 10-4320-226-14Table 3-1.Operator Troubleshooting Table.(continued)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION3.ENGINEStep 1.Step 2.4.5.6.7.8.RUNS ERRATIC AFTER WARMUP.Visually inspect air cleaner indicator.a.Reset air cleaner indicator.b.Notify unitCheck fuel supply.a.Refill fuelb.Drain waterc.Notify unitlevel maintenance.source (paragraph 3.7).separator.level of maintenance.ENGINE HAS EXCESSIVE EXHAUST SMOKE.Checka.b.c.OIL PRESSUREChecka.b.fuel supply.Refill fuel source (paragraph 3.7).Drain water separator.Notify unit level of maintenance.READING LOW.engine oil level (paragraph 3.6).Refer to LO 10-4320-226-12 and addNotify unit level of maintenance.oil.NO PUMP ASSEMBLY SUCTION OR DISCHARGE PRESSURE.Check for pump prime.a.Prime pump (paragraph 2.5).b.Notify unit level maintenance.PUMP STOPS OR FAILS TO DELIVER RATED PLOW OR PRESSURE.Check that engine is operating at proper RPM.a.Adjust engine speed (paragraph 2.5).b.Notify unit level maintenance.PUMP NOISY.Check oil level in intermediate housing. (paragraph 3.7)a. Add oil in accordance with LO 10-4320-226-12.b. Notify unit level maintenance.3-3
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business