TM 10-4320-226-144.12.3 Battery Cable Maintenance.This task covers: 4.12.3.1 Removal4.12.3.3 Installation4.12.3.2 RepairINITIALSETUPToolsGeneralSafety InstructionsGeneral Mechanic’s Tool Kit (appendix B,To prevent rolling or sliding, do notSection III, Item 1)work on equipment that is not securelystabilized.Material/PartsDo not set tools on battery or batterycase.Grease (appendix E, Section II, Item 5)DO not work on battery with negativeEquipmentConditionsterminal connected.Equipment shut down, refer toDo not work on equipment withoutparagraph 2.5.1.2 or 2.5.2.2.following standard shop safetyprecautions.Battery cover removed, paragraph 3.4.4.12.3.1 Removal.To prevent rolling or sliding, do not work on equipment that is notsecurely stabilized.Ensure both wheels are secure.Do not work on battery with negative terminal connected.Failure to obey these warnings may result in serious personal injury.a.Remove two nuts (figure 4-38, 1) washers (2), one wire (3), two bolts (4)and one wire (5) from two terminals (6).b.Remove two nuts (7), washerswire (11) from two terminalsc.Remove bolt (13), lockwasherd.Remove nut (16) and terminal(8), one wire (9), two bolts (10), and one(12).(14), and terminal lug (15) from starter.lug (17) from starter solenoid.4.12.3.2 Repair.Replace damaged or missing parts.4.12.3.3 Installation.a.Install terminal lug (17) and nut (16) to starter solenoid.b.Install terminal lug (15), lockwasher (14), and bolt (13).c.Install one wire (11), two bolts (10), one wire (9), washer (8), and nuts (7)to two terminals (12).d.Install one wire (5), two bolts (4), one wire (3), two washers (2), andnuts (1) to two terminals (6).4-71