TM 5-4320-302-14
6-17.
CONNECTING ROD ASSEMBLY (CONT)
Location/Item
Action
Remarks
DISASSEMBLY
5.
Small-end bush
Clamp connecting rod in a padded vise and remove
small-end bush with piston pin bush inserter No.
131310.
CLEANING/INSPECTION
WARNING
Dry cleaning solvent is flammable and potentially dangerous to people
and property. Do not use near open flame, sparks, excessive heat, or
on hot surfaces. Flash point of P-D-680 solvent is 100° to 138F (38° to
59°C). Use solvent in a well-ventilated area, and avoid inhaling fumes.
If repeatedly exposed to fumes, seek fresh air and immediate medical
help. Avoid prolonged exposure of skin to solvent. Wash exposed skin
immediately and thoroughly.
Death or severe injury might result when compressed air is used to blow
dirt from skin or clothing. Air entering body openings is extremely
dangerous. Compressed air used for cleaning shall not exceed 100 psi
(690 kPa). Use goggles or face shield for eye protection. Do not direct
airstream against skin.
6.
Small-end
Clean thoroughly with P-D-680 cleaning solvent and
and connecting
dry with compressed air. Remove any carbon de-
rod bore
posits with wire brush. Clean connecting rod bore
with small wire brush.
6-126