B-5. EXPLANATION OF COLUMNS IN REMARKS
MAINTENANCE ALLOCATION CHART - TM-5-4320-300-14_516
TM-5-4320-300-14 Pump Centrifugal Self-Priming Gasoline Engine Driven; 6-Inch 1500 GPM Capacity At 60 Foot Head Manual
Page Navigation
503
504
505
506
507
508
509
510
511
512
513
TM 5-4320-300-14
Section II MAINTENANCE ALLOCATION CHART
(1)
(2)
(3)
(4)
(5)
(6)
Group
Maintenance Maintenance Category* Tools And
Number
Component/Assembly
Function
C
O
F
H
D
Equipment
Remarks
01
Air Cleaner
Assembly
Inspect
0.1
1
A, M
Service
0.2
Replace
0.2
0.5
02
Exhaust System
0201
Exhaust
Heat Shield
Inspect
0.1
1, 2
B
Replace
0.3
Repair
0.3
0202
Weather Cap
Inspect
0.1
1
C
Repair
0.3
Replace
0.2
0203
Exhaust Pipe
Inspect
0.1
1,2
G
Replace
0.3
0204
Muffler
Inspect
0.1
1, 2
G
Replace
0.5
0205
Exhaust
Manifold Pipe
Inspect
0.1
Replace
0.5
03
Electrical System
0301
Battery Box and Cover
Inspect
0.1
1,2
G
Replace
1.0
0302
Battery and Cables
Inspect
0.1
1,2
D, I
Test
0.2
Service
0.3
0.5
Replace
1.0
0303
Alternator
Assembly
Inspect
0.1
1, 2, 3
I, F, L, G
Replace
1.0
Test
1.0
Repair
2.5
0304
Starter Motor Assembly
Inspect
0.1
1, 2, 3
I, H, G
Replace
0.5
Test
0.8
Repair
2.0
0305
Main Wiring Harness
Inspect
0.2
1, 2, 3
I, J
Replace
2.0
Repair
1.0
*See footnote on page B-8
B-4