TM 5-4320-275-13 & P
FRAME ASSEMBLY (CONT)
LOCATION/ITEM
ACTION
REMARKS
1. Straightening
Straighten distorted or bent structural members
of the frame assembly.
2. Aligning
Measure for frame assembly align-
ment. The mounting holes for the
diaphragm clamp must measure
10.50 0.015 inch (266.70
+0.38 mm) center-to-center. Align
frame assembly if required.
5-5