TM 5-4320-275-13 & P
CLAMP ASSEMBLY (CONT)
LOCATION/ITEM
ACTION
REMARKS
DISASSEMBLY
1. Studs
Use 1/2 inch stud removing and installing
tool to remove studs (1): from con-
necting rod clamp (2).
INSPECTION
2. Threads
Inspect threads on studs. (1) and threads in con-
necting rod clamp (2) for damage. Replace
damaged parts.
3. Connecting
Inspect connecting rod clamp (2) for cracks or
rod clamp
warpage. Replace if damaged.
CLEANING
WARNING
Clean parts in a well-ventilated area. Avoid inhalation of solvent fumes and prolonged
exposure. of skin to cleaning solvent. Wash exposed skin thoroughly. Dry cleaning solvent
(fed spec P-D,680) used to clean parts is potentially dangerous to personnel and property. Do
not use near open flame or excessive heat. Flash point of solvent is 100 (38 ).
F
C
4. Studs and
Clean studs and connecting rod clamp with
connecting
cleaning solvent, P-D-680. Use a stiff-bristle
rod clamp
brush to remove caked dirt.